CÔNG TY TNHH MỘT THÀNH VIÊN ĐỒNG VỊ PHÓNG XẠHN OFFICE: Tầng 3, 24 Hoàng Quốc Việt, Cầu Giấy, Hà Nội HCM OFFICE: 265 Gò Dưa,Thị trấn 2,P.Tam Bình,Q. Thủ Đức, HCM, VN Tel: 02437349566 Email: info@dvpx.vn |
Mô tả
The Ranger EXP is a high performance, durable, lightweight radiation detector for field use or in your facility. The Ranger EXP is designed specifically for individuals operating in tough environments. The small, handheld Geiger counter offers excellent sensitivity to NORM and low levels of alpha, beta, gamma, and x-rays. The digital readout is displayed with a red count light and a beeper sounds with each count detected. Other features include an adjustable timer, selectable alert, and with the free Observer USB Software Family, you can download your collected data, and set alarms!Detector
RAP-RS2 Probe – External Probe Halogen-quenched, uncompensated GM tube with thin mica window, 1.4-2.0 mg/cm2 areal density. Effective diameter of window is 45 mm (1.75 in.).
Operating Range
mR/hr – .001 (1µR) to 100
CPM – 0 to 350,000
µSv/hr – .01 to 1000
CPS – 0 to 5000
Total Counts- 1 to 9,999,000 counts
Energy Sensitivity
Detects Alpha down to 2 MeV. Detects Beta down to .16 MeV; typical detection efficiency at 1 MeV is approx. 25%. Detects Gamma down to 10 KeV through the detector window. 3340 CPM/mR/hr (137Cs). Smallest detectable level for 125I is .02 µCi at contact.
Built-In Efficiencies
Sulfur (35S), Strontium (90Sr/y), Cesium (137Cs), Phosphorus (32P), Carbon (14C), Iodine (131I), Cobalt (60Co), and Alpha
Accuracy
Reference to Cs137
Typically ±15% from factory, ±10% with NIST Source Calibration NIST Calibration Additional
Accuracy
Reference to Cs137
Typically ±15% from factory, ±10% with NIST Source Calibration NIST Calibration Additional
Accuracy
Reference to Cs137
Typically ±15% from factory, ±10% with NIST Source Calibration NIST Calibration Additional
Selectable Alert Settings
mR/hr .001 – 100 and CPM 1 – 350,000. 70db @ 1m. Pulsating beeper sounds the alert. Adjustable alert levels are used for mR/hr / CPM, and µSv/hr / CPS. Alarm will sound when in Timer Mode when set alarm threshold is reached.
Averaging Periods
Display updates every 3 seconds. At low background levels, the update is the average for the past 30-second time period. The timed period for the average decreases as the radiation level increases.
Display
Graphic LCD with Backlight
Outputs
![]()
![]()
![]()
![]()
![]()
![]()
USB for use with Free Observer USB Software for PCs
Bluetooth for use with the Free Observer BLE App for Android.
Count Light
Red LED flashes with each radiation event.
Audio Indicator
Internally mounted beeper (can be switched off for silent operation)
Power Requirements
USB Power or Two (2) AA alkaline batteries (included). Approx. 800 hrs @ background.
Temperature Range
-10° to +50°C (14° to 122°F)
Humidity
10% to 70% Non-Condensing.
Size
140 X 68 X 33 mm (5.5 X 2.7 X 1.3 in.)
Probe: 260 X 70 X 25 mm (10.25 X 2.75 X 1 in.)
Weight
570 g (1.25 lbs.)
Người gửi / điện thoại