CÔNG TY TNHH MỘT THÀNH VIÊN ĐỒNG VỊ PHÓNG XẠHN OFFICE: Tầng 3, 24 Hoàng Quốc Việt, Cầu Giấy, Hà Nội HCM OFFICE: 265 Gò Dưa,Thị trấn 2,P.Tam Bình,Q. Thủ Đức, HCM, VN Tel: 02437349566 Email: info@dvpx.vn |
Số lượng
Mô tả
EPD DKG-21 EcotestCARD Personal Gamma Radiation Dosimeter In 2011, the Ministry of Emergency Situations of Ukraine granted EcotestCARD dosimeters to Japan as humanitarian aid for recovery from the accident at the Fukushima NPP, where they gained a reputation of reliable and precise products.
Meets the requirements of IEC 61526 standard
Conforms to the CE standards
Its integral rechargeable battery can be powered from 220 V
As a direct reading personal dosimeter for personnel exposure monitoring it can be used either independently or within the automated system of personal monitoring.
Description
The dosimeter allows storing dose accumulation history with real time reference in the nonvolatile memory, and communicating it to the computer via the infrared port. Upon that the mode of dosimeter’s power supply switching off is blocked until the procedure of reading the information accumulated in the dosimeter is finished. The special software makes it possible to keep a database of personnel radiation burden with the ability to represent reporting information in graphical and tabular form, as well as export it to various formats.
It is possible to set values of threshold levels for dose and dose rate. If the preset threshold levels are exceeded, light and audio alarms are actuated.
The device uses an energy-compensated Geiger-Muller counter. It is powered from the lithium-ion storage battery that can be further charged from 220 V through a USB port.
Purpose of use
• Measures dose rate Hp(10) of gamma and X-ray radiation
• Measures dose Hp(10) of gamma and X-ray radiation
Branches of use
• NUCLEAR POWER INDUSTRY
• MEDICINE
• RADIOLOGICAL LABORATORY
• EMERGENCY SERVICES AND CIVIL DEFENSE
• SANITARY DOSIMETRY AND ECOLOGY
• RADIOACTIVE WASTE STORAGE SITES
• INDUSTRY
EPD DKG-21 EcotestCARD Personal Gamma Radiation Dosimeter
- In 2011, the Ministry of Emergency Situations of Ukraine granted EcotestCARD dosimeters to Japan as humanitarian aid for recovery from the accident at the Fukushima NPP, where they gained a reputation of reliable and precise products.
- Meets the requirements of IEC 61526 standard
- Conforms to the CE standards
- Its integral rechargeable battery can be powered from 220 V
As a direct reading personal dosimeter for personnel exposure monitoring it can be used either independently or within the automated system of personal monitoring.
Description
The dosimeter allows storing dose accumulation history with real time reference in the nonvolatile memory, and communicating it to the computer via the infrared port. Upon that the mode of dosimeter’s power supply switching off is blocked until the procedure of reading the information accumulated in the dosimeter is finished. The special software makes it possible to keep a database of personnel radiation burden with the ability to represent reporting information in graphical and tabular form, as well as export it to various formats.
It is possible to set values of threshold levels for dose and dose rate. If the preset threshold levels are exceeded, light and audio alarms are actuated.
The device uses an energy-compensated Geiger-Muller counter. It is powered from the lithium-ion storage battery that can be further charged from 220 V through a USB port.
Purpose of use
- Measures dose rate Hp(10) of gamma and X-ray radiation
- Measures dose Hp(10) of gamma and X-ray radiation
Branches of use
- NUCLEAR POWER INDUSTRY
- MEDICINE
- RADIOLOGICAL LABORATORY
- EMERGENCY SERVICES AND CIVIL DEFENSE
- SANITARY DOSIMETRY AND ECOLOGY
- RADIOACTIVE WASTE STORAGE SITES
INDUSTRY
Người gửi / điện thoại