Characteristics
Digital densitometer FMD-12 is a portable battery-powered
densitometer designed for measuring radiograph blackening
using an external light source. It has been developed for
bulb negatoscopes (it can also be used on negatoscopes
with fluorescent and LED light, we recommend recalibration
of the instrument using a densitometric etalon, e.g.
FOMASTEP E-09).
Technical Description
Densitometer FMD-12 consists of the actual measuring
instrument, the measuring probe, and the connecting
shielded cable. The connector for connecting the probe
using the shielded cable is located on the face of the
instrument under the display and protected against
spontaneous disconnecting. The measuring probe is of a
pencil design with a plastic black case and it is connected to
the instrument using a short cable and it is removable.
Densitometer FMD-12 is equipped with semi-automatic zero
setting and automatic turning off, when the instrument is not
used.
Instrument Recalibration
Densitometer FMD-12 allows for recalibration according to
ASME SE–1079 or ASTM E 1079–85 (“Standard practice
for calibration of Transmission densitometers") using the
setting element located on the upper right side of the
instrument. The recommended interval for repeated linearity
checking or instrument recalibration is 90 days. For
instrument recalibration, we recommend using FOMASTEP
E-09 densitometric etalons.
Supply Subject
– Densitometer FMD-12
– Measuring probe
– Connecting cable with a USB connector
– Battery 9V (type 6F22)
– Calibration sheet
– Operating manual
– Suitcase
Instrument Advantages
– Very high accuracy thanks to the use of an integrated
circuit with a capability to logarithm in 5 decades with an
error of 0.2%
– Zeroing with any light
– One of the smallest densitometers in the market




Phản hồi

Người gửi / điện thoại

Nội dung

 
 

Director

  Bùi Mạnh Cường
 +84 935130000
 cuong@dvpx.vn

Deputy Director

  Đào Văn Chỉnh
 +84 902 234 487
 services@dvpx.vn

  

Technical Chief

  Nguyễn Văn Cường
 +84 962331933
  technic@dvpx.vn

Transport Dept

  Bùi Minh Phương
 +84 968 377 899
  logistics@dvpx.vn

  2015 Manager by Cuong Nguyen Van - Tel: +84 9 62331933 All information on the website is the copyright of Radioisotopes one member company limited